01 Jan 2000
Home  »    »   Hyperterminal Serial Port Test

Hyperterminal Serial Port Test

Posted in HomeBy adminOn 07/10/17

Ontrak Control Systems manufactures serial RS232, RS485, USB Data Acquisition and Control Interfaces. GPIB to serial RS 2. This project fills the need of anybody who has a test. GPIB port and likes to get the screen dump on his PC. GPIB card. It emulates the HP7. Hyperterminal Serial Port Test' title='Hyperterminal Serial Port Test' />2 Introduction to the Controller. Cisco 4400 series wireless LAN controllers offer the highest level of performance and scalability for large scale enterprise. When you purchase a MegaSquirt kit, the components typically arrive individually packed, with part numbers. As a result, while you should verify that you have. A operation on the GPIB side. HP GL data at the RS 2. PC by any suitable software. The operation of this interface is not just. GPIB. Device addressable or listener only can be captured and brought out to. RS 2. 32 port, including raw data from the instrument or rasterized data. GPIB graphic printer. GPIB addresses and other set and forget. It is based on a PIC1. F6. 28. A microcontroller, and the PCB size is. SCHEMATIC AND DETAILSThe hardware of Pic Plot interface is quite simple the. PIC1. 6F6. 28. A, a 5. V regulator and three. External connections are a GPIB connector, a Serial port and. DC power connector. The microcontroller does all the necessary jobs to. GPIB Device functionality, in both Listener and Talker mode, by recognizing. Handshake lines. Controller mode is not needed for the intended functionality, and. Once the device is addressed and it receives. Talker, the same data are forwarded to the COM port at 9. UART inside the PIC1. F6. 28. A generates the serial data. PC through the RS2. Only in Setup mode the data flow. The RS 2. 32 connector on the. DB 9, and should be connected to the PC using. PCs missing the COM port but equipped with an USB port. USB to serial converter. Virtual Com Port drivers are properly. A jumper is provided to enter Setup mode when Pic Plot. Setup mode. In this mode the microcontroller UART is used to. GPIB cable can be left. Setup mode the GPIB port is not. Pic Plot. For normal operation this jumper must be left. More details about Setup mode can be found in the USE. AND OPERATION section. Power supply can be any voltage between 8 and 1. V, and. current drain is far below 2. A. With such a large supply requirements, a. V wall adaptor can be used as a power source. Connector polarity is center positive. An interesting possibility for. USB to serial bridge is to bypass the Pic Plot 5. V. onboard regulator and spill the 5. V supply from the USB connector mounted. This solution of course asks for a simple modification of. USB cable, then it is suggested only to people. You can find. details by clicking here. Pic plot. 2. which directly supports GPIB USB conversion. Here below the pictures of the PCB layout we have. If you want to build by yourself a similar equipment. PCB. We can also provide mounted and. PCB and schematic files, together with a quick. Back to. top. SOFTWAREThe serial data available at the DB9 connector of the. Pic Plot interface can be either captured using a communication software like Hyper Terminal. Data files should be. HPGL data or. txt in case of raw ASCII measurement data and then post processed. Captured, processed and stored using a specific SW that manages the. GPIB bus. A very good example for screen dump. HPGL plots is the 7. John Miles it. perfectly manages device initiated plots, displays them on the PC. For example, the. HP8. 75. 3A. screenshot taken with Pic Plot and the 7. More details about. John Miles KE5. FX. Plot. example of 8. A VNAPlot. example of 8. SNAPlot. example of 3. A Curve Tracer. Plot. TDS7. 54. C Oscilloscope. Plot. example of 8. E Spectrum Analyzer. There are also good commercial solutions that can be. Plottergeist and Print. Capture. We have tested. Print. Capture during the 3. GPIB capabilities of some oscilloscopes using our Pic Plot. Print. example of 3. A Curve Tracer. Print. TDS6. 44 Oscilloscope. We have also received some plot examples from Pic plot. Plot. example of Marconi 2. SA rendered with SPLOTPlot. Advantest R4. 13. SA rendered with FPLOTAnd, finally, one example sent to us by F4. EXB who has. setup a scalar bench by sweeping a PLL YIG oscillator and getting through. Pic plot the relative power readings of an HP4. GPIB option. He. Matplotlib scripts for the graphic display Plotted. HP4. 36 Microwattmeter rendered with Matplotlib. Back to top. USE AND OPERATIONBefore starting Pic Plot operates by exchanging serial data with the. PC, therefore it is assumed that EITHER your PC has a serial COM port. OR you are using an USB to serial bridge and a Virtual. Com Port VCP has been created with the appropriate drivers. Check. which COM is actually assigned to the VCP using the Control. PanelSystemPeripherals settings. Connecting the Pic Plot Connect the Pic Plot to the PC serial port using a. You can build your own cable following. Connection to the GPIB instrument must be done with a. GPIB cable. Because of limited IO capabilities of the. GBIP bus. After checking operation with a simple point to point. Connect an 81. 6V power supply or wall adaptor to the. E0001 Error In Fifa 11. Max supply current is 5. A. Setting the Pic Plot You may need to configure some basic parameters of the. Pic Plot, even though most of the times the pre programmed values will. To do this the Pic Plot must be connected to a PC and put in. Setup mode. Setup procedure maybe also useful to test the serial link. Pic Plot and the PC during first installation or when. Setup parameters are stored in the EEPROM area of the. NOTE to enter in setup mode, power must be applied to. Pic plot AFTER closing the setup jumper. Setup procedure SW version 3. E 1. Connect the Pic Plot to the PC using a null modem. This is the same cable that will be needed for normal. Launch Hyper. Terminal, specify the COM port hardware or virtual to. Pic Plot and set the communication parameters. These. are the same settings that will be needed for normal operation. Close the jumper named SETUP first and. Pic Plot. If everything is properly working, a prompt. SW version will show up on the Hyper. Terminal window. You are now. SETUP jumper if you like. You can also remove the. Setup procedure without changing any previously stored. Then you are prompted to enter a new value for the. Pic Plot will respond to. Allowed values are two. The entered value is echoed for. You are now prompted to enter a new value for the. Pic Plot will respond to. Allowed values are two. The entered value is echoed for confirmation. Next parameter to be set is the Listen On Reset. Allowed values are y or n lowercase, pre programmed value is. Set it to y yes only if you plan to connect the Pic Plot to a GPIB. System Controller capability. In this case the. Pic Plot automatically starts in Listen mode at every power on even if not. The entered value is echoed for confirmation. Dont forget to open remove the SETUP jumper for. Plot and print capturing with Pic Plot Pic Plot has no practical use where the PC is the. System Controller of the GPIB bus because instrument screen dumps can be. PC through its GPIB add on card. Visual Studio 2010 Express C# Tutorial Pdf. Its application. field, instead, is when your instrument has Controller capability or is a. Talk only GPIB device. Typical configuration is the following Be sure that Pic Plot is correctly powered. If you have. been able to complete the Setup procedure, then you are sure that Pic Plot. PC and is ready to work. To connect the instrument to the Pic Plot you need a. GPIB cable, and the instrument has to be configured exactly as it. GPIB plotter or printer refer to. The choice whether to plot or to. PC but also to. the actual capability of your instrument for example there are. GPIB graphic. printer. On the other hand, many instruments are capable to print the raw. ASCII form, and the Pic Plot is able to capture also. Excel. As a general reference, if the instrument has. What is Hyper. Terminal Definition from What. Is. com. How it works and where it came from. IT professionals and users can work with Hyper. Terminal to set up a dial up connection to another computer through the internal modem using Telnet or to access a bulletin board system in another computer. They can use Hyper. Terminal to set up a connection for data transfers between two computers, such as a desktop computer and a portable computer, using the serial ports. Hyper. Terminal can also allow IT to take serial port control of external devices or systems such as scientific instruments, robots or radio communications stations. By submitting your personal information, you agree that Tech. Target and its partners may contact you regarding relevant content, products and special offers. You also agree that your personal information may be transferred and processed in the United States, and that you have read and agree to the Terms of Use and the Privacy Policy. IT professionals can also use Hyper. Terminal to troubleshoot any issues when setting up and using a modem. IT can send commands through Hyper. Terminal to make sure the modem is properly connected. Developed by Hilgraeve from a more comprehensive communications program called Hyper. Access, Hyper. Terminal has features similar to the Linux program, Minicom. In Windows XP, IT can locate Hyper. Download Telecharger Driver Pc Camera Gratuit more. Terminal in the Start menu Start Programs Accessories Communications Hyper. Terminal. Hyper. Terminal and Windows 1. Microsoft phased out Hyper. Terminal, and it has not been included in a Windows OS since Windows XP and is not a part of Windows 1. Organizations working with Windows 1. Hyper. Terminal separately, and it does work with the OS. The download does not come from Microsoft itself, however. How to download and install Hyper. Terminal in Windows 1. Even though Hyper. Terminal is not a part of Windows 1. Windows 1. 0 operating system does provide Telnet support, but it is not enabled by default. IT can enable Telnet support by opening the Control Panel and clicking on Programs, then Turn Windows Features On or Off. Upon doing so, Windows will display a list of OS features. Select the Telnet client checkbox and click OK. Unlike Hyper. Terminal, the Windows 1. Telnet utility is command line only and does not support any of the non Telnet related features found in Hyper. Terminal. IT can launch the Telnet client by going to C WindowsSystem.